Configure the Management Port

Command:  CM (Configure Management). The HSM must be offline or in the secure state.

Function:     To configure the Management port, which is an Ethernet port used only for management of the HSM. If connection to the host is via Ethernet then the Ethernet host port is used for that purpose.

Inputs:        IP address.
Default gateway address.
Subnet mask.

Outputs:      None.

Errors:        None.

Example:

Offline>CM <Return>

Management Ethernet Port:

Enter IP address: 192.168.200.90 <Return>

Enter default gateway address: 192.168.200.1 <Return>
Enter subnet mask: 255.255.255.0 <Return>

Default settings for the Management port are meaningless and before first use must be changed to values suitable for the local connection. Once set, the values are retained as the new default values until they are changed again by the CM command.